2008 Furnace Comparison Chart

2008 Competitive Comparisons

90+% AFUE Furnaces (Fully Modulating)

as of January 1, 2008

Manufacturer

Frigidaire

Carrier

Rheem

York

Lennox

Feature

Heat Input Range (KBTU/Hr)

60-120

60-120

60-120

60-120

70-110

AFUE%

97

up to 95

94.1

95

95

Height

34

40

34

33

40

Installation Capability

Upflow/Hor

4 position

Upflow

Upflow

upflow

Ignition System

HSI - SiN

HSI - SiN

Direct Spark

HIS - SiC

HSI - SiN

Primary Heat Exchanger

Tube - Al. Steel

Clamshell - Al. Steel

Tube Stainless

Tube - Al. Steel

Clamshell

Secondary Heat Exchanger

Stainless

Polypropylene/ Laminated Steel

Stainless

Stainless

Stainless

Heat Exchanger Warranty

Limited Lifetime

Limited Lifetime

Limited Lifetime

Limited Lifetime

Limited Lifetime

Unit Replacement Warranty (years)

10 years

n/a

Limited Lifetime

n/a

n/a

Parts Warranty (years)

10 years

5 years

5 years

5 years

limited 10 yrs

Insulated Blower Compartment

Yes

Yes

Yes

Yes

Sealed Burner Compartment

Yes

No

Yes

No

yes

Sealed Blower Compartment

Yes

No

Yes

No

No

Modulation Capacity Range

15-100%

unknown

40%-100%

unknown

40%-100%

Blower Motor

Energy Efficient

Energy Efficient

Energy Efficient

PSC

Energy Efficient

Draft Inducer

Variable Speed

unknown

Two-Speed

Variable Speed

Variable Speed

Venting

1 or 2 pipe (side only)

1 or 2 pipe (side only)

1 or 2 pipe (top only)

1 or 2 pipe (top only)

1 or 2 pipe (side only)

Dehumidification Option

Yes

Yes

Yes

Yes

Yes

PCB Location

Burner Compartment

Blower Compartment

Blower Compartment

Blower Compartment

Blower Compartment

= competitive advantage

C:\2008 Furnace Competitive Comparison - Frig.xls