Learn more about heat exchangers for hot water, pools, radiant in-floor heat from hot water tanks…..
Wednesday, December 7th, 2011Generac accessories decora trim, plugs, paint
Tuesday, December 6th, 2011Great plumbing fixtures for Muskoka start your design here.
Wednesday, November 30th, 2011Who has always wanted a throne of a toilet? Comfort Height, Elongated, Quiet Close Seat
Tuesday, November 29th, 2011How to size your new Muskoka stand-by Generac generator –
Friday, November 25th, 2011What is GeoExchange
Friday, November 18th, 2011GeoExchange is the industry’s term used to describe an alternative to traditional oil- gas- or coal-fired heating, ventilation and air conditioning (HVAC) systems. Geoexchange systems have also been referred to as earth energy systems, or geothermal heat pump systems.
The idea is to take advantage of the ground’s heating and cooling properties (the same properties that make any basement cooler in the summer and warmer in the winter) to heat or cool entire buildings. This heat ‘exchange’ between the ground and the building is accomplished by using standard pump and compressor technology.
The advantages of geoexchange technology include:
- Geoexchange technology can save the developer or consumer up to 70% on their current heating bills, because it transfers existing heat without combustion,
- Geoexchange often pays for itself in less time than a traditional HVAC system, depending on current building heat/cool use, soil types, size of installation, and other factors.
- Geoexchange qualifies as a renewable energy – a typical two bedroom house-sized installation is equivalent to taking two cars off the road or planting one acre of trees.
- Geoexchange systems involve no combustion, so they are cleaner and safer to handle than either oil or gas.
- Geoexchange takes up much less space than traditional HVAC systems, they are particularly suitable for situations where space is at a premium and/or aesthetics matter.
For more information about geoexchange energy, please read our Geothermal FAQ which includes several questions regarding different subjects as the goeexchange technology,geothermal systems installation, costs and savings of a geothermal installation …
CGC Canadian Geo Exchange Accredited Design and Installation
Wednesday, November 16th, 2011Retro-Line is an internal heat tracing system designed to provide freeze protection of existing (CSA 75 PSI or CSA 100 PSI) polyethylene water supply line without their removal
Wednesday, November 9th, 2011Product Information
Retro-Line is an internal heat tracing system designed to provide freeze protection of existing (CSA 75 PSI or CSA 100 PSI) polyethylene water supply line without their removal. In order to make Retro-Line easy to install, Heat-Line developed a unique dispensing system called “Retro-Reel” to deploy the product with absolute ease, while protecting it from mechanical injury during installation. Retro-Line can be used in a variety of water supply pipe applications including, cottages, homes, resorts and farms. Insulation and an optional thermostat can be used to optimize energy efficiency.
IMPORTANT BENEFIT
A special benefit of Retro-Line often overlooked, is the fact that entire piping systems can be pre-installed and tailored to size, prior to determining Retro-Line length. An example of this flexibility would be; purchasing and installing 200 feet of pipe to the intake or pump location deep in the lake. After this is accomplished the required length of Retro-Line can be measured and installed to freeze-protect the pipe to a point below the lake ice near the shoreline. In other words, 200 feet of pipe may be installed, while only 100 feet requires freeze-protection.
Product Application
Retro-Line is an internal heat tracing system designed to provide freeze protection for existing polyethylene water supply lines. Heat-Line recommends Retro-Line to be installed in certified water pipes with pressure systems below 75 PSI. In a high pressure or constant pressure system see CARAPACE.
Retro-Line can be used in lake, river, drilled or dug well applications. In a lake application, the internal heating cable should terminate in the lake at a minimum depth of 6′ from LOW water mark. This is to be certain the pipe will be freeze protected below ice level to maintain free-flowing water within the pipes entire length. In areas where the recommended depth cannot be reached, contact Heat-Line for advice. A dug shore well, or other methods may be considered – check with local ministries, and authorities.
In a dug well application, the heating cable can pass through the length of the pipe down to the pump or foot valve as required. Care must be given not to pass the heating cable through foreign fittings with internal burrs. These fittings should be replaced with products furnished by Heat-Line.
In a drilled well application, the heater can run the length of the pipe, but cannot enter the pitless adapter or it may sustain damage. If the pitless adapter is above grade, Heat-Line suggests installing a well tile around the steel well casing and filling with earth. There are other methods of protecting these applications; consult Heat-Line for specific application requirements.
In applications where pipes will be exposed to atmosphere (free air), installed over rocky terrain or under buildings, insulation is required to maintain heat within the pipe and ensure energy efficiency and reliability.
Specifications
- cCSAus approved (Canada and USA)
- 120 Volt systems – 3watt /ft. at 50°F maximum length of 250 ft.
- 240 Volt systems – 3watt/ft. at 50°F maximum length 550 ft.
- 27 milliamp ground fault circuit interrupter plug-in device
Benefits of Retro-Line
- cCSAus approved (Canada and USA)
- 5 year limited warranty
- Most reliable and energy efficient system on the market
- Job-ready based on specific freeze protection requirements
- Poly pipe can be installed and tailored to suit requirements before Retro-Line length is determined, allowing installation flexibility
- Can be used with any type of control device including timers and thermostats
- Can be buried and/or fully insulated to increase energy efficiency
- No need to excavate below the frost line, thus saving costs on installation.
- Will never melt or burnout a water pipe, even if the pipe is dry.
- Retro-Line can be easily installed in most existing polyethylene pipes, without their removal.
- Fast Installation – Retro-Line comes ready to use, on a special patented dispensing reel, which provides excellent installation performance.
- Retro-Line is available to fit existing polyethylene pipes from ¾” up to 2″ in size.
- Philmac® compression fittings ensure pressure connections are simple, secure and leak proof.
- Available in lengths from 6′ to 550′
- Ground fault protection is integral to the system.
- Simply plugs into a 120V or 240V receptacle. No extra electrical work is required.
- No other product combines these features and offers the reliability of Retro-Line
Included in a Retro-Line system
- Specified length of self-regulating heating cable
- Compression style fitting available from ¾” to 2″ (Internal Diameter) to interface with existing water supply system
- 27 milliamp GFCI (ground fault circuit interrupter) electrical plug in device
Below are several downloadable documents about Retro-Line:
Retro-Line Brochure
Retro-Line French Brochure
Installation Guide 1
Generac Stand-by generators Maintenance Kits
Tuesday, November 8th, 2011A scheduled maintenance program ensures the generator system is always in top operating condition and warranty requirements are being met. Generac’s scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. Oil must be purchased separately based upon manufacturer recommendations listed below. Maintenance is recommended at every 200 hours or 2 years.
Kit contents may vary by model.
Kits Include:
- Air Filter
- Oil Filter
- Spark Plugs
- Oil Funnel
- Chamois
- Reminder Sticker